Lymphocyte radiosensitivity: An extension to the linear-quadratic model? - Applications Médicales et Industrielles (LPC Caen)
Article Dans Une Revue Radiotherapy & Oncology Année : 2024

Lymphocyte radiosensitivity: An extension to the linear-quadratic model?

Résumé

Background and purpose: The linear-quadratic (LQ) model has been pivotal for evaluating the effects of radiation on cells, but it is primarily characterized by linear responses, which has exhibited limitations when applied to lymphocyte data. The present research aims to address these limitations and to explore an alternative model extended from the conventional LQ model. Materials and methods: literature providing lymphocyte counts from assays investigating apoptosis and survival after in vitro irradiation was selected. To address the nonlinearity in lymphocyte responses to radiation, we developed a saturation model characterized by a negative exponential relationship between radiation dose and cellular response. We compared the performance of this saturation model against that of conventional models, including the LQ model and its variants (linear model LM and linear-quadratic-cubic model LQC), as well as the repair-misrepair (RMR) model. The models were evaluated based on prediction-residual plots, residual standard errors, and the Akaike information criterion (AIC). We applied the saturation model to two additional datasets: (1) a dataset from the existing literature that assessed stimulated and unstimulated human lymphocytes exposed to gamma irradiation in vitro and (2) a novel dataset involving T lymphocytes from rodent spleens after exposure to various radiation types (X-rays and protons). Results: The literature (n=15 out of 2342) showed that lymphocyte apoptosis varies with dose, time and experimental conditions. The saturation model had a lower AIC of 718 compared to the LM, LQ, LQC and RMR models (AIC of 728, 720, 720 and 734, respectively). The saturation model had a lower residual error and more consistent error distribution. Integrating time as a covariate, the saturation model also had a better AIC for demonstrating time-dependent variations in lymphocyte responses after irradiation. For datasets involving unstimulated lymphocytes before irradiation, the saturation model provided a more accurate fit than did the LM, LQ, and RMR models. In these cases, the fit of the saturation model was comparable to that of the LQC model but offered an advantage when extrapolating to higher doses, where the LQC model might underestimate survival. For stimulated lymphocytes, which are radioresistant, all the models approximated the LM. Both the LQ and saturation models indicated greater radiosensitivity to protons in vitro. Conclusion: The new “saturation model” performed better than the LQ model in quantifying lymphocyte apoptosis and survival, estimating time dependency and assessing the role of radiation modalities or lymphocyte stimulation. Further experiments are warranted to experimentally explore the validity of the saturation model as a promising alternative in the clinical setting.
Fichier sous embargo
Fichier sous embargo
0 0 2
Année Mois Jours
Avant la publication
mercredi 25 décembre 2024
Fichier sous embargo
mercredi 25 décembre 2024
Connectez-vous pour demander l'accès au fichier

Dates et versions

hal-04624287 , version 1 (25-06-2024)

Identifiants

Citer

Thao-Nguyen Pham, Julie Coupey, Juliette Thariat, Samuel Valable. Lymphocyte radiosensitivity: An extension to the linear-quadratic model?. Radiotherapy & Oncology, 2024, 198, pp.110406. ⟨10.1016/j.radonc.2024.110406⟩. ⟨hal-04624287⟩
71 Consultations
2 Téléchargements

Altmetric

Partager

More